Anticancer Res ; 41(11): 5821-5825, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: covidwho-1503030

RESUMEN

AIM: Anastomotic leakage (AL) in left-sided colorectal cancer is a serious complication, with an incidence rate of 6-18%. We developed a novel predictive model for AL in colorectal surgery with double-stapling technique (DST) anastomosis using auto-artificial intelligence (AI). PATIENTS AND METHODS: A total of 256 patients who underwent curative surgery for left-sided colorectal cancer between 2017 and 2021 were included. In addition to conventional clinicopathological factors, we included the type of circular stapler using DST, conventional double-row circular stapler (DCS) or EEA™ circular stapler with Tri-Staple™ technology, 28 mm Medium/Thick (Covidien, New Haven, CT, USA) which had triple-row circular stapler (TCS) as a covariate. Auto-AI software Prediction One (Sony Network Communications Inc.) was used to predict AL with 5-fold cross validation. Predictive accuracy was assessed using the area under the receiver operating characteristic curve. Prediction One also evaluated the 'importance of variables' (IOV) using a method based on permutation feature importance. RESULTS: The area under the curve of the AI model was 0.766. The type of circular stapler used was the most influential factor contributing to AL (IOV=0.551). CONCLUSION: This auto-AI predictive model demonstrated an improvement in accuracy compared to the conventional model. It was suggested that use of a TCS may contribute to a reduction in the AL rate.


Asunto(s)
Fuga Anastomótica/etiología , Colectomía/efectos adversos , Neoplasias Colorrectales/cirugía , Técnicas de Apoyo para la Decisión , Aprendizaje Automático , Grapado Quirúrgico/efectos adversos , Anciano , Fuga Anastomótica/diagnóstico , Bases de Datos Factuales , Femenino , Humanos , Masculino , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Engrapadoras Quirúrgicas , Grapado Quirúrgico/instrumentación , Factores de Tiempo , Resultado del Tratamiento
2.
Surg Today ; 51(3): 447-451, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: covidwho-1453756

RESUMEN

Accumulation of experience and advances in techniques and instruments have enabled surgeons to perform video-assisted thoracic surgery (VATS) safely for sublobar resection, including segmentectomy and wedge resection. A key to successful VATS sublobar resection is to have adequate resection margins and the appropriate use of articulated surgical staplers is essential for this purpose. The SigniaTM stapling system (Covidien Japan, Tokyo) has been used extensively in the fields of thoracic surgery. Its features include high maneuverability with fully powered articulation, rotation, clamping, and firing, which the surgeon can control with one hand. We introduce the "sliding technique" using the SigniaTM system, which allows for adjustment of the resection lines of the pulmonary parenchyma to optimize safe surgical margins with minimal stapler movement, and without repetitively moving the stapler in and out of the pleural cavity, during VATS sublobar resection.


Asunto(s)
Neoplasias Pulmonares/cirugía , Pulmón/cirugía , Márgenes de Escisión , Neumonectomía/instrumentación , Neumonectomía/métodos , Engrapadoras Quirúrgicas , Grapado Quirúrgico/instrumentación , Grapado Quirúrgico/métodos , Cirugía Torácica Asistida por Video/instrumentación , Cirugía Torácica Asistida por Video/métodos , Humanos , Seguridad
3.
J Invest Surg ; 33(1): 59-66, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: covidwho-1455005

RESUMEN

Background: Bipolar sealing devices are routinely used to seal blood vessels. The aim of the study is to evaluate the feasibility and safety of colonic sealing with the use of the bipolar energy devices in rats as model for experimental appendectomy. Methods: Seventy-five male Wistar rats underwent a cecal resection with four different bipolar sealing devices or a linear stapler. The harvesting procedure was performed immediately or at postoperative day (POD) 7. The sealing front bursting pressure (BP) was measured in both groups. At POD7, the resection line was clinically examined and the hydroxyproline (HDP) levels were determined. Hematoxylin and Eosin (H&E) staining was used for histopathological evaluation of the sealing front as well. Results: There was no mortality and no insufficiency. The BPs between the bipolar sealing devices showed no statistical differences. The early phase of the seal (POD 0) provides a low BP with an 30.8% increase until POD 7. The BPs in the stapler group showed significant better values. The hydroxyproline levels did not differ statistically between the groups. Histopathologically, there were more signs of ischemic necrosis in the stapler group than in the sealing devices groups. Conclusion: The resection and sealing of the cecum as an experimental appendectomy model with the use of bipolar energy devices proved feasible and safe in rats. The different energy devices in this study produce comparable results. To justify clinical practice in humans, several studies on the underlying mechanisms of early stage wound healing are needed.


Asunto(s)
Apendicectomía/instrumentación , Ciego/cirugía , Electrocoagulación/instrumentación , Hemostasis Quirúrgica/instrumentación , Técnicas de Cierre de Heridas/instrumentación , Animales , Apendicectomía/efectos adversos , Apendicectomía/métodos , Electrocoagulación/métodos , Estudios de Factibilidad , Hemostasis Quirúrgica/efectos adversos , Hemostasis Quirúrgica/métodos , Masculino , Modelos Animales , Ratas , Ratas Wistar , Engrapadoras Quirúrgicas/efectos adversos , Técnicas de Cierre de Heridas/efectos adversos
4.
Sci Rep ; 10(1): 5189, 2020 03 23.
Artículo en Inglés | MEDLINE | ID: covidwho-1454803

RESUMEN

Stapled hemorrhoidopexy has a few advantages such as less postoperative pain and faster recovery compared with conventional hemorrhoidectomy. There are two major devices used for stapled hemorrhoidopexy, PPH stapler (Ethicon EndoSurgery) and DST stapler (Covidien). This study was conducted to investigate the postoperative outcomes among patients with grade III and IV hemorrhoids who underwent hemorrhoidopexy with either of these two devices. A total of 242 consecutive patients underwent stapled hemorrhoidopexy with either PPH stapler (110 patients) or DST stapler (132 patients) at a single center in 2017. We performed a retrospective case-control study to compare the short-term postoperative outcomes and the complications between these two groups. After matching the cases in terms of age, gender, and the grade of hemorrhoids, there were 100 patients in each group (PPH versus DST). There were no significant differences in the postoperative visual analog scale (VAS) score and analgesic usage. Among complications, the incidence of anorectal stricture was significantly higher in the DST group (p = 0.02). Evaluation of the mucosal specimen showed that the total surface area, the muscle/mucosa ratio and the surface area of the muscle were also significantly higher in the DST group (p = 0.03). Further analysis of the DST group demonstrated that patients with anorectal stricture after surgery are younger than patients without anorectal stricture, and higher muscle/mucosa ratio (p = 0.03) and a higher surface area of the muscle (p = 0.03) also measured in the surgical specimen. The two devices provide similar outcomes of postoperative recovery. Patients who underwent DST stapled hemorrhoidopexy had a higher incidence rate of stricture, larger area of muscle excision, and higher muscle/mucosa ratio in the surgical specimen. Further investigation is warranted for a better understanding of the correlation between muscle excision and anorectal stricture.


Asunto(s)
Hemorreoidectomía/instrumentación , Hemorroides/cirugía , Engrapadoras Quirúrgicas , Acetaminofén/uso terapéutico , Canal Anal/patología , Analgésicos/uso terapéutico , Enfermedades del Ano/etiología , Constricción Patológica/etiología , Diseño de Equipo , Femenino , Hemorragia/etiología , Humanos , Mucosa Intestinal/patología , Isoxazoles/uso terapéutico , Masculino , Persona de Mediana Edad , Tamaño de los Órganos , Dolor Postoperatorio/tratamiento farmacológico , Dolor Postoperatorio/etiología , Dolor Postoperatorio/prevención & control , Complicaciones Posoperatorias/etiología , Estudios Retrospectivos , Resultado del Tratamiento , Retención Urinaria/etiología
5.
Surg Today ; 52(2): 260-267, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: covidwho-1453757

RESUMEN

PURPOSE: Postoperative pancreatic fistula (POPF) remains the most clinically relevant complication of laparoscopic distal pancreatectomy (LDP). The present study evaluated the efficacy of the "slow firing method" using a reinforced triple-row stapler (Covidien, Tokyo, Japan) during LDP. METHODS: This retrospective single-center study included 73 consecutive patients who underwent LDP using the slow firing method. A black cartridge was used in all patients. The primary endpoint was the rate of clinically relevant POPF (CR-POPF) after LDP. Secondary endpoints included perioperative outcomes and factors associated with CR-POPF as well as the correlation between the transection time and thickness of the pancreas. RESULTS: Four patients (5.5%) developed CR-POPF (grade B). Overall morbidity rates, defined as grade ≥ II and ≥ III according to the Clavien-Dindo classification, were 21 and 11%, respectively. The median postoperative hospital stay was 10 days. Preoperative diabetes (13.6 vs. 0.2%, P = 0.044) and thickness of the pancreas ≥ 15 mm (13.8% vs. 0%, P = 0.006) were identified as independent risk factors for CR-POPF. The median transection time was 16 (8-29) min. CONCLUSION: The slow firing method using a reinforced triple-row stapler for pancreatic transection is simple, safe, and effective for preventing CR-POPF after LDP.


Asunto(s)
Laparoscopía/métodos , Pancreatectomía/métodos , Fístula Pancreática/prevención & control , Complicaciones Posoperatorias/prevención & control , Engrapadoras Quirúrgicas , Grapado Quirúrgico/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Glicósidos , Humanos , Masculino , Persona de Mediana Edad , Tempo Operativo , Pregnanos , Factores de Riesgo , Seguridad , Grapado Quirúrgico/instrumentación , Resultado del Tratamiento , Adulto Joven